Type: | Water-Cooled |
---|---|
Cooling Method: | Water-cooled |
Unit Structure: | Integral |
Selected Voltage: | 380V/50HZ |
Compressor Number: | 1 or 2 |
Noise Level: | Ultra Low |
Customization: |
---|
Suppliers with verified business licenses
Model(HTLT-***) | 3W | 5W | 6W | 8W | 10WD | 12WD | 15WD | 20WD | 25WD | 30WD | 40WD | ||||
Nominal cooling capacity | -10ºC | kw | 4.4 | 7.8 | 9.6 | 12.1 | 15.6 | 19.2 | 24.2 | 33.22 | 38.2 | 46.6 | 70.2 | ||
-20ºC | 2.8 | 5.0 | 6.1 | 7.4 | 10.0 | 12.2 | 14.8 | 21.3 | 25 | 29.4 | 41.5 | ||||
-30ºC | 1.31 | 2.1 | 2.8 | 4.3 | 4.9 | 5.6 | 7.9 | 11.2 | 13.7 | 16.1 | 24.3 | ||||
-35ºC | 0.85 | 1.3 | 1.9 | 2.8 | 3.3 | 3.8 | 5.3 | 7.8 | 9.4 | 13.8 | 18.5 | ||||
Condenser | Type | Shell and tube | |||||||||||||
Cooling water flow | -10ºC | m³/h | 1 | 1.7 | 2.03 | 2.62 | 3.6 | 4.27 | 5.2 | 7.23 | 8.54 | 10.4 | 14 | ||
-20ºC | 0.61 | 0.92 | 1.09 | 1.82 | 2.03 | 2.37 | 3.04 | 4.56 | 5.6 | 6.58 | 8.61 | ||||
-30ºC | 0.31 | 0.49 | 0.65 | 1 | 1.14 | 1.3 | 1.84 | 1.61 | 3.19 | 3.74 | 4.93 | ||||
-35ºC | 0.2 | 0.31 | 0.44 | 0.65 | 0.77 | 0.89 | 1.23 | 1.81 | 2.18 | 3.2 | 4.13 | ||||
Pipe connection | inch | 1 | 1 | 1 | 1-1/2 | 2 | 2 | 2 | 2-1/2 | 2-1/2 | 3 | 3 | |||
Evaporator | Chilled water volume | -10ºC | m³/h |
0.77 | 1.33 | 1.56 | 2.01 | 2.77 | 3.28 | 4 | 5.56 | 6.57 | 8.01 | 10.75 | |
-20ºC | 0.47 | 0.71 | 0.91 | 1.4 | 1.69 | 1.82 | 2.34 | 3.51 | 4.3 | 5.06 | 6.62 | ||||
-30ºC | 0.23 | 0.36 | 0.48 | 0.74 | 0.84 | 0.96 | 1.36 | 1.93 | 2.36 | 2.77 | 3.65 | ||||
-35ºC | 0.15 | 0.22 | 0.33 | 0.48 | 0.57 | 0.65 | 0.92 | 1.34 | 1.62 | 2.37 | 3.06 | ||||
Type | shell and tube/ss plate heat exchanger | ||||||||||||||
Pipe connection | inch | 1 | 1 | 1 | 1-1/2 | 2 | 2 | 2 | 2-1/2 | 2-1/2 | 3 | 3 | |||
Input power | kw | 2.35 | 3.55 | 4.35 | 5.35 | 6.75 | 8.35 | 10.8 | 17.2 | 21 | 24.8 | 31.4 | |||
Power source | 3PH 380V~415V 50HZ/60HZ | ||||||||||||||
Refrigerant | Type | R22/R404A | |||||||||||||
Control | Thermostatic expansion valve | ||||||||||||||
Compressor | Type | Hermetic scroll(semi-hermetic piston) | |||||||||||||
Motor Power | kw | 1.8 | 3.0 | 3.8 | 4.8 | 3.0*2 | 3.8*2 | 4.8*2 | 7.5*2 | 9.4*2 | 11.3*2 | 13.7*2 | |||
Pump | Power | kw | 0.55 | 0.55 | 0.55 | 0.55 | 0.75 | 0.75 | 1.2 | 2.2 | 2.2 | 2.2 | 5.5 | ||
Lift | M | 20 | 20 | 20 | 20 | 20 | 20 | 20 | 20 | 20 | 20 | 20 | |||
Safety devices | compressor inner protection, over current protection, high/low pressure protection, over temperature protection, flow rate protection, phase sequence/phase missing protection, low level coolant protection, anti freezing protection, exhaust overheat protection | ||||||||||||||
Dimension | Length | mm | 890 | 890 | 890 | 1300 | 1500 | 1500 | 1780 | 1950 | 1650 | 1880 | 2225 | ||
Width | mm | 550 | 550 | 550 | 680 | 760 | 760 | 850 | 850 | 850 | 980 | 950 | |||
Height | mm | 1055 | 1055 | 1055 | 1385 | 1385 | 1385 | 1800 | 1960 | 1650 | 1800 | 1915 | |||
Net weight | kg | 135 | 175 | 210 | 310 | 450 | 530 | 750 | 835 | 920 | 1080 | 1125 | |||
The above specifications are according to the following design conditions: 1.Condensing temperature 35ºC 2.Volume fraction of glycol water solution 47.8% We reserve the right to modify the specifications without further notice. |
Model(HTSL-***) | 40W | 50W | 60W | 75W | 85W | 100W | 120W | 150W | 180W | 200W | 240W | 270W | |||||||
Nominal cooling capacity | -10ºC | kw | 81.9 | 106.5 | 117.8 | 159 | 183.4 | 212.2 | 252.3 | 316.7 | 390.6 | 453.9 | 535.5 | 597.7 | |||||
-20ºC | 55.9 | 72.7 | 80.3 | 108.5 | 125.1 | 144.7 | 172.1 | 216.0 | 266.5 | 309.6 | 365.3 | 407.7 | |||||||
-30ºC | 35.7 | 46.4 | 51.3 | 69.3 | 80.0 | 92.5 | 110.0 | 138.1 | 170.3 | 197.9 | 233.5 | 260.6 | |||||||
Input Power | kw | 33 | 42 | 47 | 62 | 70 | 80 | 97 | 121 | 148 | 170 | 202 | 222 | ||||||
Power source | 3PH 380V~415V 50HZ/60HZ | ||||||||||||||||||
Refrigerant | Type | R22/R404A | |||||||||||||||||
Charge | kg | 28 | 35 | 42 | 52.5 | 59.5 | 70 | 84 | 105 | 126 | 140 | 168 | 189 | ||||||
Control | Thermostatic expansion valve | ||||||||||||||||||
Compressor | Type | Semi-hermetic screw | |||||||||||||||||
Motor power | kw | 33 | 42 | 47 | 62 | 70 | 84 | 97 | 121 | 148 | 170 | 202 | 222 | ||||||
Start mode | Y-△ | ||||||||||||||||||
Capacity control | % | 0-25-50-75-100 | |||||||||||||||||
Evaporator | Type | Shell and tube(ss plate heat exchanger) | |||||||||||||||||
Chilled water volume | -10ºC | m³/h | 12.4 | 16.1 | 17.5 | 21.3 | 27.7 | 32 | 38.2 | 48 | 59 | 68.8 | 80.6 | 90.8 | |||||
-20ºC | 8.3 | 10.8 | 11.9 | 14.4 | 18.6 | 21.5 | 25.6 | 32.3 | 39.7 | 46.4 | 54.3 | 61.2 | |||||||
-30ºC | 5.1 | 7.1 | 8.4 | 10.3 | 13.4 | 15.5 | 18.4 | 23.2 | 28.7 | 33.4 | 39 | 44 | |||||||
Water pressure drop | kPa | 32 | 35 | 38 | 42 | 45 | 40 | 43 | 45 | 45 | 45 | 47 | 47 | ||||||
Pipe connection | inch | 3 | 3 | 3 | 3 | 4 | 4 | 4 | 5 | 6 | 6 | 6 | 6 | ||||||
Condenser | Type | Shell and tube | |||||||||||||||||
Cooling water flow | m³/h | 25 | 32.3 | 35.5 | 43.3 | 60 | 65 | 77 | 96.8 | 119.2 | 138.8 | 162.8 | 183.5 | ||||||
Water pressure drop | kPa | 42 | 42 | 45 | 43 | 45 | 48 | 46 | 48 | 48 | 48 | 48 | 48 | ||||||
Pipe connection | m³/h | 3 | 3 | 3 | 3 | 3 | 4 | 4 | 3*2 | 3*2 | 4*2 | 4*2 | 4*2 | ||||||
Safety devices | compressor inner protection, over current protection, high/low pressure protection, over temperature protection, flow rate protection, phase sequence/phase missing protection, low level coolant protection, anti freezing protection, exhaust overheat protection | ||||||||||||||||||
Dimension | Length | mm | 2500 | 2550 | 2600 | 2750 | 2800 | 2900 | 3000 | 3300 | 3800 | 3900 | 4300 | 4500 | |||||
Width | mm | 780 | 780 | 780 | 780 | 950 | 950 | 1200 | 1380 | 1380 | 1380 | 1480 | 1480 | ||||||
Height | mm | 1650 | 1650 | 1650 | 1650 | 1950 | 1950 | 1580 | 1630 | 1750 | 1750 | 1780 | 1780 | ||||||
Net weight | kg | 920 | 1100 | 1250 | 1600 | 1900 | 2100 | 2550 | 2750 | 3250 | 3450 | 3950 | 4260 | ||||||
Running weight | kg | 1050 | 1250 | 1400 | 1780 | 2100 | 2300 | 2750 | 3000 | 3500 | 3750 | 4250 | 4560 | ||||||
The above specifications are according to the following design conditions 1.Condensing temperature 35ºC 2.Volume fraction of glycol water solution 47.8% We reserve the right to modify the specifications without further notice |
Model(HTSL-***) | 100WD | 120WD | 150WD | 170WD | 200WD | 240WD | 280WD | 300WD | 360WD | 400WD | 460WD | 480WD | 540WD | |||
Nominal cooling capacity | -10ºC | kw | 213 | 235.6 | 318.0 | 366.8 | 424.4 | 504.6 | 599.8 | 633.4 | 781.2 | 907.8 | 997.0 | 1071 | 1195.4 | |
-20ºC | 145.4 | 160.6 | 217.0 | 250.2 | 289.4 | 344.2 | 409.2 | 432.0 | 533.0 | 619.2 | 680.0 | 730.6 | 815.4 | |||
-30ºC | 92.8 | 102.6 | 138.6 | 160.0 | 185.0 | 220.0 | 261.6 | 276.2 | 340.6 | 395.8 | 434.6 | 467.0 | 521.2 | |||
Input Power | kw | 84 | 94 | 124 | 140 | 160 | 194 | 230 | 242 | 296 | 340 | 380 | 404 | 444 | ||
Power source | 3PH 380V~415V 50HZ/60HZ | |||||||||||||||
Refrigerant | Type | R22/R404A | ||||||||||||||
Charge | kg | 35*2 | 42*2 | 52.5*2 | 59.5*2 | 70*2 | 84*2 | 98*2 | 105*2 | 126*2 | 140*2 | 161*2 | 168*2 | 189*2 | ||
Control | Thermostatic expansion valve | |||||||||||||||
Compressor | Type | Semi-hermetic screw | ||||||||||||||
Motor power | kw | 42*2 | 47*2 | 62*2 | 70*2 | 84*2 | 97*2 | 115*2 | 121*2 | 148*2 | 170*2 | 190*2 | 202*2 | 222*2 | ||
Start mode | Y-△ | |||||||||||||||
Capacity control | % | 0-25-50-75-100 | ||||||||||||||
Evaporator | Type | Shell and tube(ss plate heat exchanger) | ||||||||||||||
Chilled water volume | -10ºC | m³/h | 32.2 | 35 | 42.6 | 55.4 | 64 | 76.4 | 90.8 | 96 | 118 | 137.6 | 151 | 161.2 | 181.6 | |
-20ºC | 21.6 | 23.8 | 28.8 | 37.2 | 43 | 51.2 | 61.2 | 64.6 | 79.4 | 92.8 | 101.8 | 108.6 | 122.4 | |||
-30ºC | 14.2 | 16.8 | 20.6 | 26.8 | 31 | 36.8 | 44 | 46.4 | 57.4 | 66.8 | 73.2 | 78 | 88 | |||
Water pressure drop | kPa | 42 | 42 | 46 | 43 | 45 | 45 | 43 | 48 | 44 | 45 | 42 | 45 | 46 | ||
Pipe connection | inch | 4 | 4 | 5 | 6 | 6 | 6 | 8 | 8 | 8 | 8 | 10 | 10 | 10 | ||
Condenser | Type | Shell and tube | ||||||||||||||
Cooling water flow | m³/h | 64.7 | 71 | 86.6 | 120 | 130 | 154 | 183.4 | 193.6 | 238.4 | 277.6 | 305 | 232.6 | 367 | ||
Water pressure drop | kPa | 41 | 42 | 42 | 45 | 48 | 46 | 48 | 48 | 46 | 42 | 48 | 48 | 48 | ||
Pipe connection | m³/h | 4 | 4 | 3*2 | 3*2 | 4*2 | 4*2 | 4*2 | 5*2 | 5*2 | 5*2 | 5*2 | 6*2 | 6*2 | ||
Safety devices | compressor inner protection, over current protection, high/low pressure protection, over temperature protection, flow rate protection, phase sequence/phase missing protection, low level coolant protection, anti freezing protection, exhaust overheat protection | |||||||||||||||
Dimension | Length | mm | 2800 | 2950 | 3150 | 3480 | 3480 | 3650 | 3650 | 3750 | 4230 | 4230 | 4350 | 4350 | 4420 | |
Width | mm | 780 | 810 | 850 | 875 | 895 | 1120 | 1300 | 1380 | 1380 | 1480 | 1450 | 1560 | 1650 | ||
Height | mm | 1650 | 1650 | 1750 | 1850 | 1850 | 1950 | 1950 | 2100 | 2150 | 2250 | 2250 | 2300 | 2450 | ||
Net weight | kg | 1950 | 2300 | 2650 | 2900 | 3550 | 4050 | 4200 | 4550 | 5100 | 5350 | 5600 | 5850 | 6100 | ||
Running weight | kg | 2250 | 2500 | 2950 | 3300 | 3950 | 4450 | 4600 | 5050 | 5600 | 5950 | 6300 | 6450 | 6700 | ||
The above specifications are according to the following design conditions 1.Condensing temperature 35ºC 2.Volume fraction of glycol water solution 47.8% We reserve the right to modify the specifications without further notice. |
Brand strength | We are the professional and top supplier of industrial chiller with 20 years experience. |
Professional Guidance | Professional and experienced technician & sales team service to the oversea market, offering professional solution according to requirements; |
Fast delivery | 1/2hp to 50hp air-cooled chillers in stock for immediately delivery; |
Golden service | Service call response within 1 hour, solution offered within 4hrs, and own oversea installation and maintenance team |
Suppliers with verified business licenses